What is CROHMIQ® brand fabric?
Why is CROHMIQ unique?
What is a Type C FIBC?
What is a Type D FIBC?
Why is a Type D FIBC preferable to a Type C FIBC?
How are static hazards identified?
What are CENELEC and the IEC?
How are Type D FIBC tested?
What testing has been done on CROHMIQ?
Can CROHMIQ FIBC be reused?
How do you evaluate Type D FIBC?
Where are CROHMIQ FIBC purchased?
Myths & Misconceptions Explained...

What is CROHMIQ® brand fabric?

CROHMIQ fabric is a patented, woven polypropylene static protective Type D fabric used in the manufacture of ungrounded bulk bags or FIBC (Flexible Intermediate Bulk Container) for use in flammable gas, vapor and dust atmospheres. FIBC constructed of CROHMIQ fabric provide static protection by dissipating the static charge buildup on the FIBC and by limiting the energy of discharges to prevent an ignition of the flammable environment.

CROHMIQ static protective FIBC are used by Fortune 500 companies and others in a wide range of applications where flammable gas or vapor such as ethylene, toluene or methane or flammable dust such as corn starch, resins, and fertilizers are present.

CROHMIQ FIBC have an outstanding safety record with over 15 million FIBC used since 1995.

Return to Top

Why is CROHMIQ unique?

Special patented static dissipative yarns in the fabric dissipate the static charge by corona discharge.

The use of CROHMIQ static protective FIBC eliminates the need for operators to ground the FIBC prior to filling or emptying. The static dissipative performance is provided by the fabric and does not require special FIBC construction methods. The static dissipative property does not deteriorate over the life of the FIBC and maintains its protective properties through multiple refurbishment cycles.

Return to Top

What is a Type C FIBC?

Type C FIBC use a conductive surface or network to conduct the static charge from the surface of the FIBC to a ground. These FIBC provide safe and effective static protection only if they are well constructed and properly grounded. All conductive elements within the Type C FIBC must be interconnected to the grounding tab which in turn must be grounded during filling and emptying of the FIBC.

Return to Top

What is a Type D FIBC?

Type D FIBC do not require grounding to provide safe, effective protection from hazardous static discharges. The fabric has antistatic properties that dissipate the static charges safely to prevent small sparks and potentially explosive discharges. CROHMIQ's design engineers invented Type D technology and was awarded its first patent in 1995. CENELEC created the Type D FIBC classification after the introduction of the revolutionary CROHMIQ technology.

Return to Top

Why is a Type D FIBC preferable to a Type C FIBC?

According to industry experts, a leading cause of industrial accidents involving FIBC is a Type C FIBC with a broken or missing ground connection (see Britton's article). Isolated Type C FIBC is extremely dangerous because they can produce energetic sparks that can easily ignite flammable gas and vapor and most flammable dust atmospheres. The proper grounding of Type C FIBC is prone to human error. FIBC made of CROHMIQ static protective Type D FIBC fabric have no special construction requirements and do not require grounding.

Return to Top

How are static hazards identified?

The potential static hazards at the locations where FIBC are filled and emptied are dependent on the type and form of the product conveyed, the material handling system during filling or emptying, the flammable environment, and the safety procedures in use. Just as FIBC have a 5:1 or 6:1 safe working load, the FIBC should have a level of safety on static protection. An evaluation of the materials used, machinery, and processes is required to determine the static discharge hazard.

Return to Top

What are CENELEC and the IEC?

CENELEC, the European Committee for Electrotechnical Standardization, was created in 1973 and is a non-profit technical organization composed of the National Electrotechnical Committees of 23 European countries.

The IEC (International Electrotechnical Commission) was founded in 1906 in St. Louis, Missouri, and is presently comprised of 40 countries including the U.S.A. Its stated purpose is to establish standards for a wide variety of electrical products to encourage international trade.

Return to Top

How are Type D FIBC tested?

Charging rate (current), Minimum Ignition Energy (MIE) of the flammable material, and relative humidity are the critical test parameters to establish performance.

The test method closely simulates industrial handling of powders using a test apparatus that fills and empties a FIBC with polypropylene pellets under controlled environmental conditions. A flammable gas probe is used to measure the ignition hazard of the static discharges from the FIBC using gas mixtures of defined MIE. This method is incorporated in the International test standard IEC-61340-4-4.

Return to Top

What testing has been done on CROHMIQ?

CROHMIQ FIBC have been successfully tested using the method described in IEC 61340-4-4 since 1995 by leading test laboratories, customers, and even competitors under a wide variety of test conditions. TEXENE maintains a state of the art testing facility as part of its ongoing commitment to safety, research, and new product development.

Return to Top

Can CROHMIQ FIBC be reused?

CROHMIQ static protective FIBC have been refurbished with wet and dry cleaning processes and reused by customers. A properly designed program for refurbishment including safety testing may allow multiple reuses of a CROHMIQ FIBC.

Return to Top

How do you evaluate Type D FIBC?

When purchasing Type D FIBC for your application, it is important to understand the nature of the static hazard and the level of safety required to protect your employees and customers. The FIBC is just one element of an electrostatically safe and effective material handling system. Look carefully at the test method, the MIE, and the charging rates used, to determine safe performance level.

Return to Top

Where are CROHMIQ FIBC purchased?

TEXENE is proud to offer CROHMIQ fabric to a global network of FIBC Suppliers. These leading FIBC manufacturers will design, produce, and deliver FIBC made of CROHMIQ static protective Type D FIBC fabric to your specifications anywhere in the world. CROHMIQ fabric is available in two colors, CROHMIQ blue™ and CROHMIQ white™. Contact our Sales & Service staff for more information or to locate.

Return to Top

TEXENE LLC, Textile Technologies of the 21st Century
Textile Technologies of the 21st Century


TEXENE LLC is a leading manufacturer of technical textiles focused on delivering precision engineered, safety performance products worldwide.

ARTICLES ON ELECTROSTATICS

STATIC HAZARDS USING FLEXIBLE INTERMEDIATE BULK CONTAINERS FOR POWDER HANDLING
In the early 1990's, Dr Laurence G. Britton, a highly respected process safety engineer with Union Carbide Corp. (later Dow Corp.), conducted a study of fire and explosion incidents that occurred when FIBC were ...

DANGERS OF COMBUSTIBLE DUST EXPLOSIONS, OSHA REGULATIONS, AND ANTISTATIC FIBC
Following three fatal dust explosions in 2003 alone, the US Chemical Safety & Hazard Investigation Board (CSB) launched a wide ranging study of industrial dust explosions.  This first issue of our Electrostatic Safety ...

CHOOSING SAFE STATIC CONTROL FIBC
The second issue of our Electrostatic Safety Review outlines the development of conductive Type C FIBC and the later development of CROHMIQ, the world's first truly effective Type D FIBC fabric, which provides ...

TESTING & CERTIFYING THE SAFETY OF STATIC PROTECTIVE FIBC
The third issue in our series of Electrostatic Safety Reviews describes the rigorous testing that is demanded by national and international standards such (IEC, CENELEC, NFPA, etc.) in order to prove the safety of ...

NEW DEVELOPMENTS IN SAFETY STANDARDS FOR STATIC PROTECTIVE FIBC
Companies that handle combustible powders in bulk bags, or empty products from bulk bags in environments where flammable solvents may be present rely on safe antistatic FIBC to prevent fires and explosions. Proving safety ...

CHEMICAL ACCIDENTS IN THE NEWS

Feb 3rd, 2012
Gas well fire extinguished in Mercer County
A compressor at a Mercer County gas well caught fire early today. The fire was ...

Feb 2nd, 2012
Chemical spill at Middleburg Academy cancels school, one adult hospitalized
Loudoun Fire and Rescue received a call this morning regarding a chemical spill at Middleburg ...

Feb 2nd, 2012
1 hurt in grain elevator explosion
The Hutchinson News ARLINGTON – One man has been taken by ambulance to a Wichita hospital ...

Feb 2nd, 2012
Plant fire extinguished in Dickson, no injuries
DICKSON, Tenn. (AP) — A fire at a Dickson automotive plant has been extinguished and production ...

Feb 2nd, 2012
Welder's spark caused blaze that destroyed Box Elder recycling plant
DEWEYVILLE — Damage may top $1 million in a Wednesday afternoon fire that destroyed a 7,500-square-foot recycling ...

Feb 1st, 2012
Man injured in explosion at Shrewsbury business
SHREWSBURY, Pa. (WHTM) - A 21-year-old man was injured when vapors in a metal drum ...

Jan 31st, 2012
Calif. salami plant to pay $700K for ammonia leak
SAN FRANCISCO The owners of a South San Francisco salami plant will pay nearly $700,000 and ...

Jan 30th, 2012
Workers escape Muskegon Co. factory before explosion
NORTON SHORES, Mich. (NEWSCHANNEL 3) – On Monday dozens of workers had a very close call, escaping ...

Jan 30th, 2012
One Person Transported After Explosion at Madison Chemistry Building
The Madison Fire Department responded to the UW Madison Chemistry Building on the morning of ...

Jan 30th, 2012
Crews finish clean up of minor chemical leak at BASF Corp. in Belvidere
Crews tearing down a tower at the former BASF Corp. chemical plant in Belvidere ruptured ...

Jan 28th, 2012
Welding work sparks explosion, fire in Hyannis
HYANNIS – Welding work and a gas leak sparked an explosion Friday morning at an automobile ...

Jan 28th, 2012
Employees escape injury at Bryant Industries fire
DANVILLE — Two employees at Bryant Industries escaped injury Friday morning when a fire quickly ignited ...

Jan 27th, 2012
13 injured, exposed to carbon monoxide
BLACK RIVER FALLS, Wis. (AP) -- Authorities say a faulty propane tank likely caused carbon ...

Jan 26th, 2012
2 sue for injuries from fire in Derry Township
Two welders claim the negligence of workers for an Oklahoma gas well drilling company resulted ...

Jan 24th, 2012
Investigation of oil well blast ongoing
Enid News and Eagle The Enid News and Eagle Mon Jan 23, 2012, 10:42 PM CST ENID — Oklahoma ...

Jan 24th, 2012
Pinellas Park warehouse evacuated due to chemical reaction
PINELLAS PARK, Fla. - A Pinellas Park warehouse was evacuated after a hazardous material spilled. ...

Jan 21st, 2012
Rig explosion near Marshall injures three
Last Modified: 1/21/2012 2:27 PM MARSHALL — An oil rig explosion in northwest Logan County injured three people ...

Jan 21st, 2012
Toxics from Suncor refinery spill still seeping into water; Colorado vows to "accelerate" response
Black goo is still seeping into waterways from Suncor Energy's oil refinery north of Denver, ...

Jan 20th, 2012
3 hurt in fiery well site explosion near Pearsall
PEARSALL, Texas (AP) - Authorities say three workers have been injured in a fiery explosion ...

Jan 19th, 2012
60-gallon chemical spill triggers haz-mat response at Solutia plant in Indian Orchard
This is an update of a story that was posted at 3:41 p.m. Thursday SPRINGFIELD ...

Jan 19th, 2012
Large Fire in Plantsville
The fire is at 200 Clark St. in Southington....

Jan 19th, 2012
Cause of fire under investigation
GEORGE WEST – The cause of a tank complex fire Friday at Key Energy Services Inc. ...

Jan 19th, 2012
Scrap metal fire enters its third day
The Gazette A rubber tire particle fire at Berkeley Scrap Metal in Moncks Corner is ...

Jan 19th, 2012
Fuel tank explosion sends local man to hospital
A local man using an arc welder on an old fuel tank was sent to ...

Jan 19th, 2012
Blast burns Green River man
| Loading… CASPER, Wyo. — A Green River man was badly burned during an on-the-job explosion in ...

Jan 18th, 2012
Glass embedded in student's chest, abdomen in lab explosion
A University of Florida laboratory explosion last week caused chemical burns on a graduate student's ...

Jan 18th, 2012
Cedar Rapids water plant chlorine leak repaired
CEDAR RAPIDS, Iowa (AP) — Firefighters have stopped a chlorine leak that set off an alarm ...

Jan 17th, 2012
Spark in auto shop ignited large fire
COLUMBIA STATION — A spark from a cutting torch accidentally igniting gasoline is believed to have ...

Jan 17th, 2012
Chemical Leak At Avondale Investigated
No injuries reported Authorities are investigating the cause of a chemical leak at the Avondale ...

Jan 17th, 2012
Workers help put out fire at U.S. Steel site in West Mifflin
Production resumed on Sunday at the U.S. Steel Mon Valley Works Irvin Plant after ...