CHOOSING SAFE STATIC CONTROL FIBC

CHOOSING A SAFE STATIC PROTECTIVE FIBC by Dr. Paul Holdstock, Texene LLC.

Static electricity is created whenever materials come into contact, rub together and separate. This is a process known as tribocharging. If one or other of the materials is insulating, the charges generated can remain in place indefinitely and can lead to hazardous electrostatic discharges. With powder and granular materials, the surface area available for charging is greatly increased compared to solid materials. When such materials are conveyed through ducts and chutes, there is plenty of opportunity for tribocharging to occur leaving the materials highly charged.

With the introduction of flexible intermediate bulk containers (FIBC) in the late 1960's, the need for managing static electricity became a prime concern. Polypropylene, which became the material of choice for FIBC, is highly insulating and will not naturally dissipate static electricity. Any charge generated when filling a standard polypropylene FIBC cannot be dissipated. Furthermore, when the FIBC is emptied, even more charge will be generated as the contents contact and separate from the sides and discharge spout of the FIBC. Highly charged materials will inevitably give rise to electrostatic discharges that can ignite combustible dusts and any solvent vapour that may be present when FIBC are emptied.

Evolution of Static Protective FIBC
In the 1970's the first generation of static protective FIBC started to appear. The original idea was to try to make FIBC more like metal containers. Some early designs used aluminised film laminated to polypropylene fabric to make flexible "metal" containers. However, these designs soon gave way to the now common practice of weaving a grid of conductive yarns into polypropylene fabric. The conductive grid in each panel of the FIBC, i.e. sides, top, base, spouts, etc., need to be connected together and to a common grounding point, which must then be securely connected to ground. These conductive FIBC for all practical purposes behave just like metal containers in that they collect charge on the conductive grid and transport it quickly to ground.

Introduction of Type C FIBC
By the 1980's, the use of conductive FIBC was becoming widespread and industrial accidents caused by incendiary discharges from FIBC were indeed reduced. However, incidents did still occur even with conductive FIBC. A group of process safety engineers working in large chemical companies in Germany and Switzerland helped to establish the requirements for safe conductive FIBC and introduced a classification system [1]. In their system, conductive FIBC were called Type C and they had to meet certain requirements with regard to the spacing and interconnection of conductive yarns and the electrical resistance between the conductive grid and ground. The classification and design requirements were later incorporated into International Standards [2 - 4].

Dangers of Type C FIBC
When designed and built to the right requirements and when properly and securely grounded by personnel handling the FIBC, Type C FIBC offer adequate protection against hazardous electrostatic discharges. However, even with established design requirements, there were still incidents of fires and explosions being caused by incendiary discharges from Type C FIBC. During the early 1990's, Dr. L.G. Britton reported case histories on several explosion incidents caused by failure to ground Type C FIBC in the publication Process Safety Progress [5]. The grounding of Type C FIBC is their main mechanism for dissipating static electricity, but it is also their major weakness.

1) Type C FIBC Must be Grounded to Work Safely
If Type C FIBC are not grounded, or if there is a break in the electrical connections between the various parts of the FIBC, charge will still accumulate on the conductive grid but it will not be able to find its way to ground. The result is that all the charge built up on the grid is available to form a spark that will release all the stored energy at once. Such sparks are more than capable of igniting combustible dusts and solvent vapours.

2) Manufacturing & Assembly is Critical to Performance
Careful attention needs to be paid to the manufacturing and operation of Type C FIBC to ensure that all parts are properly interconnected and that the FIBC is properly and securely grounded before all filling and emptying operations. In referring to the dangers of Type C FIBC, Dr. Britton stated "In particular it should be appreciated that the potential for operator grounding error and sudden nemesis can be very high".
One approach to the potential hazards associated with Type C FIBC, is to tighten up controls during manufacture and use. Reputable and safety conscious manufacturers will ensure their production staff are fully trained and informed of the necessity to ensure electrical interconnection throughout the entire FIBC, and they will undertake 100% inspection and testing of their Type C FIBC. Unfortunately, this is not always the case as they rely on single unit, manual manufacturing processes which can vary from FIBC to FIBC. Controls have been introduced by companies using Type C FIBC in the form of interlocks that prevent filling or emptying unless there is a secure ground connection in place on the FIBC. With rigorous manufacturing control, thorough operator training, and the use of special handling equipment, Type C FIBC can be used safely. The human factor is involved in all of these controls and so there is still a finite risk of human error.

3) Human Error
Dr. Britton's report raised serious concerns within a number of large companies that shipped their products in FIBC. They realised that even if they invested in all the equipment needed to handle Type C FIBC safely and required their FIBC suppliers to carryout 100% inspection and testing, they had no control over how their customers would handle the FIBC. Many of their customers would be small companies that would not invest in expensive handling systems and may not even train their operators correctly. FIBC were needed that were inherently safe and did not need the intervention of an operator. In other words, FIBC that provide full static protection without being grounded.


CROHMIQ® Static Protective Type D FIBC - A Better Solution
CROHMIQ® Static Protective Type D FIBC were the first to provide full control over static electricity without the need for grounding. CROHMIQ® FIBC dissipate electrostatic charge safely into the atmosphere via low energy corona discharging. The components used to dissipate charge are an integral part of the woven polypropylene fabric used to construct the FIBC. Unlike Type C FIBC, there is no need to electrically interconnect the different panels in CROHMIQ® FIBC, and so manufacturing errors are automatically eliminated. There is also no need to ground CROHMIQ® FIBC, and so the need for complex and expensive grounding systems is eliminated, as is the risk of human error. CROHMIQ® FIBC are intrinsically safe and require no input from operators when filling or when emptying.

CROHMIQ® FIBC are designed and engineered to provide total electrostatic safety across a wide range of industries without the need for grounding. This unique static protective technology was pioneered by CROHMIQ's engineers in 1995. Since then, CROHMIQ® FIBC have been used to package over 30 billion pounds of products for the world's most demanding industries, including pharmaceuticals, fine chemicals, pigments, and food products. In light of the safety record established by CROHMIQ®, the concept of a static protective FIBC that does not require grounding was formally recognised in 2003 by the inclusion of Type D within the classification system specified in International Standards [2 - 4].
In addition to meeting all electrostatic safety standards, CROHMIQ® FIBC comply with FDA and EU regulations for food contact and pharmaceutical applications.
CROHMIQ® FIBC are used throughout the world by major companies as an essential part of their regulation of combustible dust hazards. Thanks to their outstanding safety record, CROHMIQ® FIBC are widely acknowledged as the safest and most cost effective solution for controlling static electricity in FIBC handling operations.

For more information about CROHMIQ® FIBC fabrics, visit www.crohmiq.com

References
[1] Mauer, B., Glor, M., Lüttgens, G. and Post, L., "Hazards associated with propagating brush discharges on flexible intermediate bulk containers, compounds and coated materials", Inst. Phys. Conf. Series No. 85, pp. 217-222, IOP Publishing Ltd 1987.
[2] CLC/TR 50404, Electrostatics - Code of practice for the avoidance of hazards due to static electricity.
[3] NFPA 654, Standard for the Prevention of Fires and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids.
[4] IEC 61340-4-4, Electrostatics - Part 4-4: Standard test methods for specific applications - Electrostatic classification of flexible intermediate bulk containers (FIBC).
[5] Britton, Laurence G., "Static hazards using flexible intermediate bulk containers for powder handling", Process Safety Progress, Vol. 12. No. 4, AIChE 1993.
CROHMIQ, CROHMIQ FIBC, CROHMIQ blue, CROHMIQ white & the blue fabric color are registered trademarks of Texene LLC. CROHMIQ technology is owned by Texene LLC and is protected by US Patents Nos. 5,478,154, 5,679,449, and 6,112,772, and additional foreign patents and patent pending.

TEXENE LLC, Textile Technologies of the 21st Century
Textile Technologies of the 21st Century


TEXENE LLC is a leading manufacturer of technical textiles focused on delivering precision engineered, safety performance products worldwide.

ARTICLES ON ELECTROSTATICS

STATIC HAZARDS USING FLEXIBLE INTERMEDIATE BULK CONTAINERS FOR POWDER HANDLING
In the early 1990's, Dr Laurence G. Britton, a highly respected process safety engineer with Union Carbide Corp. (later Dow Corp.), conducted a study of fire and explosion incidents that occurred when FIBC were ...

DANGERS OF COMBUSTIBLE DUST EXPLOSIONS, OSHA REGULATIONS, AND ANTISTATIC FIBC
Following three fatal dust explosions in 2003 alone, the US Chemical Safety & Hazard Investigation Board (CSB) launched a wide ranging study of industrial dust explosions.  This first issue of our Electrostatic Safety ...

CHOOSING SAFE STATIC CONTROL FIBC
The second issue of our Electrostatic Safety Review outlines the development of conductive Type C FIBC and the later development of CROHMIQ, the world's first truly effective Type D FIBC fabric, which provides ...

TESTING & CERTIFYING THE SAFETY OF STATIC PROTECTIVE FIBC
The third issue in our series of Electrostatic Safety Reviews describes the rigorous testing that is demanded by national and international standards such (IEC, CENELEC, NFPA, etc.) in order to prove the safety of ...

NEW DEVELOPMENTS IN SAFETY STANDARDS FOR STATIC PROTECTIVE FIBC
Companies that handle combustible powders in bulk bags, or empty products from bulk bags in environments where flammable solvents may be present rely on safe antistatic FIBC to prevent fires and explosions. Proving safety ...

CHEMICAL ACCIDENTS IN THE NEWS

Feb 3rd, 2012
Gas well fire extinguished in Mercer County
A compressor at a Mercer County gas well caught fire early today. The fire was ...

Feb 2nd, 2012
Chemical spill at Middleburg Academy cancels school, one adult hospitalized
Loudoun Fire and Rescue received a call this morning regarding a chemical spill at Middleburg ...

Feb 2nd, 2012
1 hurt in grain elevator explosion
The Hutchinson News ARLINGTON – One man has been taken by ambulance to a Wichita hospital ...

Feb 2nd, 2012
Plant fire extinguished in Dickson, no injuries
DICKSON, Tenn. (AP) — A fire at a Dickson automotive plant has been extinguished and production ...

Feb 2nd, 2012
Welder's spark caused blaze that destroyed Box Elder recycling plant
DEWEYVILLE — Damage may top $1 million in a Wednesday afternoon fire that destroyed a 7,500-square-foot recycling ...

Feb 1st, 2012
Man injured in explosion at Shrewsbury business
SHREWSBURY, Pa. (WHTM) - A 21-year-old man was injured when vapors in a metal drum ...

Jan 31st, 2012
Calif. salami plant to pay $700K for ammonia leak
SAN FRANCISCO The owners of a South San Francisco salami plant will pay nearly $700,000 and ...

Jan 30th, 2012
Workers escape Muskegon Co. factory before explosion
NORTON SHORES, Mich. (NEWSCHANNEL 3) – On Monday dozens of workers had a very close call, escaping ...

Jan 30th, 2012
One Person Transported After Explosion at Madison Chemistry Building
The Madison Fire Department responded to the UW Madison Chemistry Building on the morning of ...

Jan 30th, 2012
Crews finish clean up of minor chemical leak at BASF Corp. in Belvidere
Crews tearing down a tower at the former BASF Corp. chemical plant in Belvidere ruptured ...

Jan 28th, 2012
Welding work sparks explosion, fire in Hyannis
HYANNIS – Welding work and a gas leak sparked an explosion Friday morning at an automobile ...

Jan 28th, 2012
Employees escape injury at Bryant Industries fire
DANVILLE — Two employees at Bryant Industries escaped injury Friday morning when a fire quickly ignited ...

Jan 27th, 2012
13 injured, exposed to carbon monoxide
BLACK RIVER FALLS, Wis. (AP) -- Authorities say a faulty propane tank likely caused carbon ...

Jan 26th, 2012
2 sue for injuries from fire in Derry Township
Two welders claim the negligence of workers for an Oklahoma gas well drilling company resulted ...

Jan 24th, 2012
Investigation of oil well blast ongoing
Enid News and Eagle The Enid News and Eagle Mon Jan 23, 2012, 10:42 PM CST ENID — Oklahoma ...

Jan 24th, 2012
Pinellas Park warehouse evacuated due to chemical reaction
PINELLAS PARK, Fla. - A Pinellas Park warehouse was evacuated after a hazardous material spilled. ...

Jan 21st, 2012
Rig explosion near Marshall injures three
Last Modified: 1/21/2012 2:27 PM MARSHALL — An oil rig explosion in northwest Logan County injured three people ...

Jan 21st, 2012
Toxics from Suncor refinery spill still seeping into water; Colorado vows to "accelerate" response
Black goo is still seeping into waterways from Suncor Energy's oil refinery north of Denver, ...

Jan 20th, 2012
3 hurt in fiery well site explosion near Pearsall
PEARSALL, Texas (AP) - Authorities say three workers have been injured in a fiery explosion ...

Jan 19th, 2012
60-gallon chemical spill triggers haz-mat response at Solutia plant in Indian Orchard
This is an update of a story that was posted at 3:41 p.m. Thursday SPRINGFIELD ...

Jan 19th, 2012
Large Fire in Plantsville
The fire is at 200 Clark St. in Southington....

Jan 19th, 2012
Cause of fire under investigation
GEORGE WEST – The cause of a tank complex fire Friday at Key Energy Services Inc. ...

Jan 19th, 2012
Scrap metal fire enters its third day
The Gazette A rubber tire particle fire at Berkeley Scrap Metal in Moncks Corner is ...

Jan 19th, 2012
Fuel tank explosion sends local man to hospital
A local man using an arc welder on an old fuel tank was sent to ...

Jan 19th, 2012
Blast burns Green River man
| Loading… CASPER, Wyo. — A Green River man was badly burned during an on-the-job explosion in ...

Jan 18th, 2012
Glass embedded in student's chest, abdomen in lab explosion
A University of Florida laboratory explosion last week caused chemical burns on a graduate student's ...

Jan 18th, 2012
Cedar Rapids water plant chlorine leak repaired
CEDAR RAPIDS, Iowa (AP) — Firefighters have stopped a chlorine leak that set off an alarm ...

Jan 17th, 2012
Spark in auto shop ignited large fire
COLUMBIA STATION — A spark from a cutting torch accidentally igniting gasoline is believed to have ...

Jan 17th, 2012
Chemical Leak At Avondale Investigated
No injuries reported Authorities are investigating the cause of a chemical leak at the Avondale ...

Jan 17th, 2012
Workers help put out fire at U.S. Steel site in West Mifflin
Production resumed on Sunday at the U.S. Steel Mon Valley Works Irvin Plant after ...